1. Disconnect the door lock actuator connector.
2. Apply battery positive voltage and connect the ground to the corresponding door lock actuator terminals and inspect the door lock actuator operation.
If not as specified, replace the door lock actuator.
Actuator operation
Connection
B+
GND
Lock
A
(F)
B
(E)
Unlock
B
(E)
A
(F)
- ( )
- RH
1. Disconnect the door lock actuator connector.
2. Inspect for continuity between the door lock-link switch terminals.
If not as specified, replace the door lock actuator.
1. Disconnect the door lock actuator connector.
2. Inspect for continuity between the door lock-link switch terminals.